Advantage:
1.High light output2.High detection efficiency
3.Low cost
4.Good high temperature resistance
Advantage:
1.High light output2.High detection efficiency
3.Low cost
4.Good high temperature resistance
Kinheng can provide detectors based on PMT, SiPM, PD for radiation spectrometer, personal dosimeter, security imaging and other fields.
1. SD series detector
2. ID series detector
3. Low energy X-ray detector
4. SiPM series detector
5. PD series detector
PS-Plug Socket Module |
插座式电子模块 |
SD- Separated Detector |
分体式探头 |
ID-Integrated Detector |
集成式探测器 |
H- High Voltage |
高压电源 |
HL- Fixed High/Low Voltage |
固定值高低压电源 |
AH- Adjustable High Voltage |
可调节高压电源 |
AHL- Adjustable- High/Low Voltage |
可调高低压电源 |
MCA-Multi-Channel Analyzer |
多道分析仪 |
X-ray Detector |
x射线系列探头 |
S-SiPM Detector |
硅光电倍增管 |
Products |
|||||
Series |
Model No. |
Description |
Input |
Output |
Connector |
PS |
PS-1 |
Electronic module with socket, 1”PMT |
14 Pins |
||
PS-2 |
Electronic module with socket& high/ low power supply-2”PMT |
14Pins |
|||
SD |
SD-1 |
Detector. Integrated 1” NaI(Tl) and 1”PMT for Gamma ray |
|
14 Pins |
|
SD-2 |
Detector. Integrated 2” NaI(Tl) and 2”PMT for Gamma ray |
|
14Pins |
||
SD-2L |
Detector. Integrated 2L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
||
SD-4L |
Detector. Integrated 4L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
||
ID |
ID-1 |
Integrated Detector, with 1” NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
ID-2 |
Integrated Detector, with 2” NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
ID-2L |
Integrated Detector, with 2L NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
ID-4L |
Integrated Detector, with 4L NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
MCA |
MCA-1024 |
MCA, USB type-1024 Channel |
14 Pins |
||
MCA-2048 |
MCA, USB type-2048 Channel |
14Pins |
|||
MCA-X |
MCA,GX16 type Connector-1024~32768 channels available |
14Pins |
|||
HV |
H-1 |
HV Module |
|||
HA-1 |
HV Adjustable Module |
||||
HL-1 |
High/Low Voltage |
||||
HLA-1 |
High/Low Adjustable Voltage |
||||
X |
X-1 |
Integrated detector-X ray 1” Crystal |
GX16 |
||
S |
S-1 |
SIPM Integrated Detector |
GX16 |
||
S-2 |
SIPM Integrated Detector |
GX16 |
Kinheng has capability for integrated
detector design. On the basis of SD series detectors, ID series detectors
integrate electronic components, simplify the interface, and make the use of
gamma ray detectors easier. Supported by integrated circuits, the ID series
detectors provide lower power consumption, lower signal noise, and more
powerful functions compared with previous devices of the same volume.
3”
detectors design
3”
ID detector connector
Model Properties |
ID-1 |
ID-2 |
ID-2L |
ID-4L |
Crystal Size |
1” |
2”&3” |
50x100x400mm/ 100x100x200mm |
100x100x400mm |
PMT |
CR125 |
CR105、CR119 |
CR119 |
CR119 |
Storage Temperature |
-20 ~ 70℃ |
-20 ~ 70℃ |
-20 ~ 70℃ |
-20 ~ 70℃ |
Operation Temperature |
0~ 40℃ |
0~ 40℃ |
0~ 40℃ |
0~ 40℃ |
HV |
0~+1250V |
0~+1250V |
0~+1250V |
0~+1250V |
Scintillator |
NaI(Tl)
|
NaI(Tl)
|
NaI(Tl) |
NaI(Tl) |
Operation Temperature |
≤70% |
≤70% |
≤70% |
≤70% |
Built-in HV |
N/A |
Optional |
Optional |
Optional |
Gain Multiplier |
1~5 |
1~5 |
1~5 |
1~5 |
Energy Resolution |
6% ~ 8% |
6% ~ 8% |
6% ~ 8.5% |
6% ~ 8.5% |
Interface Type |
GX16
|
GX16 BNC SHV |
GX16 |
GX16 |
Radiation dose measurement
Spectrum analysis
SD Series Detector
Energy Spectrum Acquisition Detector DMCA
SiPM Series Detector
PD series detector
Low energy X Ray detector