Advantage:
1.High detection efficiency
2.Replaceable
Request A QuoteAdvantage:
1.High detection efficiency
2.Replaceable
Request A QuoteKinheng can provide detectors based on PMT, SiPM, PD for radiation spectrometer, personal dosimeter, security imaging and other fields.
1. SD series detector
2. ID series detector
3. Low energy X-ray detector
4. SiPM series detector
5. PD series detector
PS-Plug Socket Module |
插座式电子模块 |
SD- Separated Detector |
分体式探头 |
ID-Integrated Detector |
集成式探测器 |
H- High Voltage |
高压电源 |
HL- Fixed High/Low Voltage |
固定值高低压电源 |
AH- Adjustable High Voltage |
可调节高压电源 |
AHL- Adjustable- High/Low Voltage |
可调高低压电源 |
MCA-Multi-Channel Analyzer |
多道分析仪 |
X-ray Detector |
x射线系列探头 |
S-SiPM Detector |
硅光电倍增管 |
Products |
|||||
Series |
Model No. |
Description |
Input |
Output |
Connector |
PS |
PS-1 |
Electronic module with socket, 1”PMT |
14 Pins |
||
PS-2 |
Electronic module with socket& high/ low power supply-2”PMT |
14Pins |
|||
SD |
SD-1 |
Detector. Integrated 1” NaI(Tl) and 1”PMT for Gamma ray |
|
14 Pins |
|
SD-2 |
Detector. Integrated 2” NaI(Tl) and 2”PMT for Gamma ray |
|
14Pins |
||
SD-2L |
Detector. Integrated 2L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
||
SD-4L |
Detector. Integrated 4L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
||
ID |
ID-1 |
Integrated Detector, with 1” NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
ID-2 |
Integrated Detector, with 2” NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
ID-2L |
Integrated Detector, with 2L NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
ID-4L |
Integrated Detector, with 4L NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
MCA |
MCA-1024 |
MCA, USB type-1024 Channel |
14 Pins |
||
MCA-2048 |
MCA, USB type-2048 Channel |
14Pins |
|||
MCA-X |
MCA,GX16 type Connector-1024~32768 channels available |
14Pins |
|||
HV |
H-1 |
HV Module |
|||
HA-1 |
HV Adjustable Module |
||||
HL-1 |
High/Low Voltage |
||||
HLA-1 |
High/Low Adjustable Voltage |
||||
X |
X-1 |
Integrated detector-X ray 1” Crystal |
GX16 |
||
S |
S-1 |
SIPM Integrated Detector |
GX16 |
||
S-2 |
SIPM Integrated Detector |
GX16 |
Kinheng
designed Be window detectors for low energy X-ray detector. According to the
traditional encapsulation method, the detection efficiency of X-ray is low. X-ray
detector used 0.2mm thickness Be window to replace traditional 0.8mm thickness aluminum
shell. The X-ray detection efficiency was improved significantly. X Series
detector follows the design idea of detachable and replaceable. It can use
either NaI(Tl) crystal with output pulse width of 1.5us or LaBr3:Ce crystal
with output pulse of 0.5us to meet the measurement requirements of high and low
doses.
X
ray detector connector
Type
Properties
XR-1
Crystal Size
1”
PMT
CR125
Storage Temperature
-20 ~ 70℃
Operation Temperature
0~ 40℃
HV
0~+1250V
Humidity
≤70%
Energy Resolution
<60%@5.9Kev(Fe-55)
Crystal Type
NaI(Tl)/CsI(Tl)
X
ray detector dimensions
SD Series Detector
Energy Spectrum Acquisition Detector DMCA
SiPM Series Detector
PD series detector
ID Series Detector