Advantage:
1.High light output2.High detection efficiency
3.Low cost
4.Good high temperature resistance
Request A Quote
Advantage:
1.High light output2.High detection efficiency
3.Low cost
4.Good high temperature resistance
Kinheng can provide detectors based on PMT, SiPM, PD for radiation spectrometer, personal dosimeter, security imaging and other fields.
1. SD series detector
2. ID series detector
3. Low energy X-ray detector
4. SiPM series detector
5. PD series detector
PS-Plug Socket Module |
插座式电子模块 |
SD- Separated Detector |
分体式探头 |
ID-Integrated Detector |
集成式探测器 |
H- High Voltage |
高压电源 |
HL- Fixed High/Low Voltage |
固定值高低压电源 |
AH- Adjustable High Voltage |
可调节高压电源 |
AHL- Adjustable- High/Low Voltage |
可调高低压电源 |
MCA-Multi-Channel Analyzer |
多道分析仪 |
X-ray Detector |
x射线系列探头 |
S-SiPM Detector |
硅光电倍增管 |
Products |
|||||
Series |
Model No. |
Description |
Input |
Output |
Connector |
PS |
PS-1 |
Electronic module with socket, 1”PMT |
14 Pins |
||
PS-2 |
Electronic module with socket& high/ low power supply-2”PMT |
14Pins |
|||
SD |
SD-1 |
Detector. Integrated 1” NaI(Tl) and 1”PMT for Gamma ray |
|
14 Pins |
|
SD-2 |
Detector. Integrated 2” NaI(Tl) and 2”PMT for Gamma ray |
|
14Pins |
||
SD-2L |
Detector. Integrated 2L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
||
SD-4L |
Detector. Integrated 4L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
||
ID |
ID-1 |
Integrated Detector, with 1” NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
ID-2 |
Integrated Detector, with 2” NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
ID-2L |
Integrated Detector, with 2L NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
ID-4L |
Integrated Detector, with 4L NaI(Tl), PMT, electronics module for Gamma ray. |
|
GX16 |
||
MCA |
MCA-1024 |
MCA, USB type-1024 Channel |
14 Pins |
||
MCA-2048 |
MCA, USB type-2048 Channel |
14Pins |
|||
MCA-X |
MCA,GX16 type Connector-1024~32768 channels available |
14Pins |
|||
HV |
H-1 |
HV Module |
|||
HA-1 |
HV Adjustable Module |
||||
HL-1 |
High/Low Voltage |
||||
HLA-1 |
High/Low Adjustable Voltage |
||||
X |
X-1 |
Integrated detector-X ray 1” Crystal |
GX16 |
||
S |
S-1 |
SIPM Integrated Detector |
GX16 |
||
S-2 |
SIPM Integrated Detector |
GX16 |
SD series detectors encapsulate crystal and
PMT into one housing, which overcomes the hygroscopic disadvantage of some crystals
including NaI(Tl), LaBr3:Ce, CLYC. When packaging PMT, internal geomagnetic shielding material
reduced the influence of geomagnetic field on the detector. Applicable for
pulse counting, energy spectrum measurement and radiation dose measurement.
2”
probe dimension
Pin definition
Model Properties |
SD-1 |
SD-2 |
SD-2L |
SD-4L |
Crystal Size |
1” |
2"&3“ |
50x100x400mm/ 100x100x200mm |
100x100x400mm |
PMT |
CR125 |
CR105、CR119 |
CR119 |
CR119 |
Storage Temperature |
-20 ~ 70℃ |
-20 ~ 70℃ |
-20 ~ 70℃ |
-20 ~ 70℃ |
Operation Temperature |
0~ 40℃ |
0~ 40℃ |
0~ 40℃ |
0~ 40℃ |
HV |
0~+1500V |
0~+1500V |
0~+1500V |
0~+1500V |
Scintillator |
NaI(Tl) |
NaI(Tl) |
NaI(Tl) |
NaI(Tl) |
Operation Humidity |
≤70% |
≤70% |
≤70% |
≤70% |
Energy Resolution |
6% ~ 8% |
6% ~ 8% |
7% ~ 8.5% |
7% ~ 8.5% |
Application:
Radiation dose measurement
Energy measurement
Spectrum analysis
Energy Spectrum Acquisition Detector DMCA