+86-21-56310568/56311668/63063530  sales@kinheng-crystal.com
English    |    中文版
  Language  
SiPM Series Detector

Advantage:

1.Compact structure

2.Easy operation

3.Low background

4.Excellent energy resolution

5.Stable output

6.High reliability and durability

7.High detection efficiency

Request A Quote
  • Kinheng can provide detectors based on PMT, SiPM, PD for radiation spectrometer, personal dosimeter, security imaging and other fields.

    1. SD series detector

    2. ID series detector

    3. Low energy X-ray detector

    4. SiPM series detector

    5. PD series detector

    PS-Plug Socket Module  

    插座式电子模块

    SD- Separated Detector   

    分体式探头

    ID-Integrated Detector

    集成式探测器

    H- High Voltage

    高压电源

    HL- Fixed High/Low Voltage

    固定值高低压电源

    AH- Adjustable High Voltage

    可调节高压电源

    AHL- Adjustable- High/Low Voltage

    可调高低压电源

    MCA-Multi-Channel Analyzer 

    多道分析仪

    X-ray Detector

    x射线系列探头

    S-SiPM Detector

    硅光电倍增管


















    Products

    Series

    Model No.

    Description

    Input

    Output

    Connector

    PS

    PS-1

    Electronic module with socket, 1”PMT

    14 Pins

    PS-2

    Electronic module with socket& high/ low power supply-2”PMT

    14Pins

    SD

    SD-1

    Detector. Integrated 1” NaI(Tl) and 1”PMT for Gamma ray

    14 Pins

    SD-2

    Detector. Integrated 2” NaI(Tl) and 2”PMT for Gamma ray

    14Pins

    SD-2L

    Detector. Integrated 2L NaI(Tl) and 3”PMT for Gamma ray

    14 Pins

    SD-4L

    Detector. Integrated 4L NaI(Tl) and 3”PMT for Gamma ray

    14 Pins

    ID

    ID-1

    Integrated Detector, with 1” NaI(Tl), PMT, electronics module for Gamma ray.

    GX16

    ID-2

    Integrated Detector, with 2” NaI(Tl), PMT, electronics module for Gamma ray.

    GX16

    ID-2L

    Integrated Detector, with 2L NaI(Tl), PMT, electronics module for Gamma ray.

    GX16

    ID-4L

    Integrated Detector, with 4L NaI(Tl), PMT, electronics module for Gamma ray.

    GX16

    MCA

    MCA-1024

    MCA, USB type-1024 Channel

    14 Pins

    MCA-2048

    MCA, USB type-2048 Channel

    14Pins

    MCA-X

    MCA,GX16 type Connector-1024~32768 channels available

    14Pins

    HV

    H-1

    HV Module

    HA-1

    HV Adjustable Module

    HL-1

    High/Low Voltage

    HLA-1

    High/Low Adjustable Voltage

    X

    X-1

    Integrated detector-X ray 1” Crystal

    GX16

    S

    S-1

    SIPM Integrated Detector

    GX16

    S-2

    SIPM Integrated Detector

    GX16















































    SiPM Series Detector

    Kinheng designed first generation SiPM scintillator detector, S series detectors use silicon photodiodes(SiPM) instead of traditional photomultiplier tubes(PMT) to detect gamma rays, and have the characteristics of small size.



    S-1dimension



    S-1 connector

    S-2 Dimension



    S-2 Connector

             Type

    Properties

    S-1

    S-2

    Crystal Size

    1”

    2”

    SIPM

    6x6mm

    6x6mm

    SIPM Numbers

    1~4

    1~16

    Storage Temperature

    -20 ~ 70

    -20 ~ 70

    Operation Temperature

    -10~ 40

    -10~ 40

    HV

    26~+31V

    26~+31V

    Scintillator

    NaI(Tl),CsI(Tl),GAGG,CeBr3,LaBr3

    NaI(Tl),CsI(Tl),GAGG,CeBr3,LaBr3

    Humidity

    ≤70%

    ≤70%

    Signal Amplitude

    -50mv

    -50mv

    Energy Resolution

    8%

    8%


    Application:

    Radiation dose measurement

    Energy measurement                        

    Spectrum analysis

    Nuclide identification



  • SD Series Detector

    Energy Spectrum Acquisition Detector DMCA

    PD series detector

    ID Series Detector

    Low energy X Ray detector

Request A Quote
Your Name(required)
Email(required)
Phone(required)
Messages(required)
Captcha(required)
Sending...

Products

Hot products